Skip to Content

DC Arc Flash Incident Energy Calculator

Explore how system voltage, fault current and the multiplication factor affect estimated incident energy and arc flash boundary distance.

Adjust the values below to calculate your scenario. The starting settings reproduce the eVehicleSafe Excel calculator.

Enable JavaScript to use this calculator. Results appear after the calculator loads.

Your calculation

V DC
0 V1,000 V

Enter the maximum voltage of the battery or module string being assessed.

A
0 A10,000 A

The workbook uses 10,000 A for EV batteries. Lower values for HEV or PHEV batteries require engineering review and a supporting risk assessment.

factor
03.0

Workbook reference: 1.0 open air; 1.5 in-box; 3.0 enclosure. The displayed factor is the value used in the calculation.

Calculation settings

These are the working distance and arcing time used by the spreadsheet formulas. Change them only to assess a supported scenario.

Estimated results

Incident energy—cal/cm²
Arc flash boundary—cm
Arcing current—A

Starting settings: 45.7 cm working distance · 0.25 s arcing time · factor 1.5

This tool reproduces the supplied spreadsheet model. An estimate alone does not establish safe working conditions or select PPE for a specific task. Use the equipment information and task-specific risk assessment.

How this calculation works

Results use the same formulas and constants as the eVehicleSafe spreadsheet, without rounding intermediate values.

Arcing current: 0.5 × bolted-fault current

Incident energy: 0.01 × (voltage × arcing current × arcing time × factor) ÷ working distance²

Arc flash boundary: √(0.003963 × factor × voltage × bolted-fault current × arcing time)

The Excel factor control uses positions 0–6 and divides the selected position by two. This web control displays the resulting factor directly, preserving that scaling. The default arcing time is the formula input of 0.25 seconds. Results are displayed to two decimal places.

Arc rating reference from the spreadsheet
PPE categoryIncident energy rangeMinimum arc rating
CAT 11.2 to 4 cal/cm²4 cal/cm²
CAT 24 to 8 cal/cm²8 cal/cm²
CAT 38 to 25 cal/cm²25 cal/cm²
CAT 425 to 40 cal/cm²40 cal/cm²

Reproduced as a reference from the workbook's second sheet. The calculator does not assign a PPE category from its calculated result.

Need help with EV workshop safety?

Talk to eVehicleSafe about training, equipment and practical support for your automotive workshop.

Contact eVehicleSafe